CHIGO INVERTER HEATPUMPS 2012

    Condenser coverd in ice after one night use, outside themperatur plus 2 C     Bottom part of condenser coverd with Ice when deicing stop.                 

                 
 

ONLY TWO THIRD OF  CONDENSER WORKING AS EVAPORATOR

 UNDER HEATING CIRCLE

LEAKING SERVICE VALVE

Chigo valves leak so bad you get sprayed with refrigerant as you are winding it backwards. We have discovered that it leak much more when the temperature is low 

Wee have to/    leaklock/threadtape the cap to stop the leak

MAIL FROM CHIGO  BEFORE PURCHASING THIS UNITS 

Dear Oyvind,                                                                                                    ti 04.05.2010 10:02

  Thank you for your kind market information for me to know. Actually ,for our inverter machine, it can also run on ambient temp.is -20 degree, but you know without good performance. With regard to CS-35V3A-*AH5 ,when system found ice or frost ,the four way valve will change to cool function automatically, so defrost the system. Yes, this is the model with patented defrosting system which is specially designed for north European market .Our patented system use a Solenoid Valve which is installed on the compressor vent pipe to defrost the bottom of condenser, and then system changes to normal defrost way by four way valves).

B.rgds!

Coco

Guangdong Chigo Air-Conditioning Co.,Ltd.

Commercial A/C Overseas Marketing

Website: www.chigogroup.com 

Direct Line: +86-757-8878  1921

Mobile: +86-13702658679

Fax: +86-757-8562 8914

Msn:rita-chigo@hotmail.com